AUREOLE-R-v3 / experiments.json
PureOne's picture
AUREOLE-R 3.0.0-hf.1: standalone public research release
9d6c005 verified
Raw
History Blame Contribute Delete
1.2 kB
{
"protocol_version": "2.0.0",
"frozen_before_first_benchmark_run": true,
"scene_ids": [200, 201, 202, 203, 204, 205, 206, 207],
"replicate_seeds": [3101, 3102, 3103],
"receiver_grid": [32, 64],
"viewport": [16, 20],
"emitter_grid_side": 6,
"rays_per_receiver_per_frame": 2,
"phases": {"cold": 4, "warm": 16, "revisit": 8, "relight": 8, "hidden_change": 8},
"unseen_ticks_before_revisit": 500,
"unseen_tick_semantics": "No observations of these receivers. This is a clock gap, not 500 fully rendered frames.",
"methods": ["raw_importance", "neural_cv", "constant_world_cv", "screen_cv", "world_cv", "world_active_cv", "world_plugin"],
"primary_comparison": "world_cv versus screen_cv expected per-channel MSE in revisit phase, equal physical ray count",
"secondary_comparisons": ["world_cv versus raw_importance", "world_active_cv versus world_cv", "world_cv versus constant_world_cv", "world_cv versus world_plugin in hidden_change phase"],
"reporting": "All methods and phases, including regressions; scene-cluster bootstrap 95% intervals; no GPU/FPS inference",
"scope": "Direct illumination of point receivers by finite point emitters behind sphere occluders"
}