new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

Sep 2

TraHGR: Transformer for Hand Gesture Recognition via ElectroMyography

Deep learning-based Hand Gesture Recognition (HGR) via surface Electromyogram (sEMG) signals has recently shown significant potential for development of advanced myoelectric-controlled prosthesis. Existing deep learning approaches, typically, include only one model as such can hardly maintain acceptable generalization performance in changing scenarios. In this paper, we aim to address this challenge by capitalizing on the recent advances of hybrid models and transformers. In other words, we propose a hybrid framework based on the transformer architecture, which is a relatively new and revolutionizing deep learning model. The proposed hybrid architecture, referred to as the Transformer for Hand Gesture Recognition (TraHGR), consists of two parallel paths followed by a linear layer that acts as a fusion center to integrate the advantage of each module and provide robustness over different scenarios. We evaluated the proposed architecture TraHGR based on the commonly used second Ninapro dataset, referred to as the DB2. The sEMG signals in the DB2 dataset are measured in the real-life conditions from 40 healthy users, each performing 49 gestures. We have conducted extensive set of experiments to test and validate the proposed TraHGR architecture, and have compared its achievable accuracy with more than five recently proposed HGR classification algorithms over the same dataset. We have also compared the results of the proposed TraHGR architecture with each individual path and demonstrated the distinguishing power of the proposed hybrid architecture. The recognition accuracies of the proposed TraHGR architecture are 86.18%, 88.91%, 81.44%, and 93.84%, which are 2.48%, 5.12%, 8.82%, and 4.30% higher than the state-ofthe-art performance for DB2 (49 gestures), DB2-B (17 gestures), DB2-C (23 gestures), and DB2-D (9 gestures), respectively.

  • 4 authors
·
Mar 28, 2022

emg2qwerty: A Large Dataset with Baselines for Touch Typing using Surface Electromyography

Surface electromyography (sEMG) non-invasively measures signals generated by muscle activity with sufficient sensitivity to detect individual spinal neurons and richness to identify dozens of gestures and their nuances. Wearable wrist-based sEMG sensors have the potential to offer low friction, subtle, information rich, always available human-computer inputs. To this end, we introduce emg2qwerty, a large-scale dataset of non-invasive electromyographic signals recorded at the wrists while touch typing on a QWERTY keyboard, together with ground-truth annotations and reproducible baselines. With 1,135 sessions spanning 108 users and 346 hours of recording, this is the largest such public dataset to date. These data demonstrate non-trivial, but well defined hierarchical relationships both in terms of the generative process, from neurons to muscles and muscle combinations, as well as in terms of domain shift across users and user sessions. Applying standard modeling techniques from the closely related field of Automatic Speech Recognition (ASR), we show strong baseline performance on predicting key-presses using sEMG signals alone. We believe the richness of this task and dataset will facilitate progress in several problems of interest to both the machine learning and neuroscientific communities. Dataset and code can be accessed at https://github.com/facebookresearch/emg2qwerty.

  • 8 authors
·
Oct 26, 2024

emg2pose: A Large and Diverse Benchmark for Surface Electromyographic Hand Pose Estimation

Hands are the primary means through which humans interact with the world. Reliable and always-available hand pose inference could yield new and intuitive control schemes for human-computer interactions, particularly in virtual and augmented reality. Computer vision is effective but requires one or multiple cameras and can struggle with occlusions, limited field of view, and poor lighting. Wearable wrist-based surface electromyography (sEMG) presents a promising alternative as an always-available modality sensing muscle activities that drive hand motion. However, sEMG signals are strongly dependent on user anatomy and sensor placement, and existing sEMG models have required hundreds of users and device placements to effectively generalize. To facilitate progress on sEMG pose inference, we introduce the emg2pose benchmark, the largest publicly available dataset of high-quality hand pose labels and wrist sEMG recordings. emg2pose contains 2kHz, 16 channel sEMG and pose labels from a 26-camera motion capture rig for 193 users, 370 hours, and 29 stages with diverse gestures - a scale comparable to vision-based hand pose datasets. We provide competitive baselines and challenging tasks evaluating real-world generalization scenarios: held-out users, sensor placements, and stages. emg2pose provides the machine learning community a platform for exploring complex generalization problems, holding potential to significantly enhance the development of sEMG-based human-computer interactions.

  • 14 authors
·
Dec 2, 2024

FLEX: A Large-Scale Multi-Modal Multi-Action Dataset for Fitness Action Quality Assessment

With the increasing awareness of health and the growing desire for aesthetic physique, fitness has become a prevailing trend. However, the potential risks associated with fitness training, especially with weight-loaded fitness actions, cannot be overlooked. Action Quality Assessment (AQA), a technology that quantifies the quality of human action and provides feedback, holds the potential to assist fitness enthusiasts of varying skill levels in achieving better training outcomes. Nevertheless, current AQA methodologies and datasets are limited to single-view competitive sports scenarios and RGB modality and lack professional assessment and guidance of fitness actions. To address this gap, we propose the FLEX dataset, the first multi-modal, multi-action, large-scale dataset that incorporates surface electromyography (sEMG) signals into AQA. FLEX utilizes high-precision MoCap to collect 20 different weight-loaded actions performed by 38 subjects across 3 different skill levels for 10 repetitions each, containing 5 different views of the RGB video, 3D pose, sEMG, and physiological information. Additionally, FLEX incorporates knowledge graphs into AQA, constructing annotation rules in the form of penalty functions that map weight-loaded actions, action keysteps, error types, and feedback. We conducted various baseline methodologies on FLEX, demonstrating that multimodal data, multiview data, and fine-grained annotations significantly enhance model performance. FLEX not only advances AQA methodologies and datasets towards multi-modal and multi-action scenarios but also fosters the integration of artificial intelligence within the fitness domain. Dataset and code are available at https://haoyin116.github.io/FLEX_Dataset.

  • 8 authors
·
Jun 1, 2025 1

EgoEMG: A Multimodal Egocentric Dataset with Bilateral EMG and Vision for Hand Pose Estimation

Surface electromyography (sEMG) records muscle activity during hand movement and can be decoded to recover detailed hand articulation. EMG and egocentric vision are complementary for hand sensing: EMG captures fine-grained finger articulation even under occlusion and poor lighting, while vision provides global hand configuration. However, no existing dataset synchronizes both modalities. We present EgoEMG, a multimodal egocentric dataset for bimanual hand pose estimation. EgoEMG includes bilateral wristband EMG with 16 total channels (8 per wrist) sampled at 2 kHz, 120 Hz IMU, egocentric wide-angle RGB video, external RGB-D video, and mocap-derived hand motion with wrist articulation angles. The dataset covers 41 participants performing 60 gesture classes, including 30 single-hand gestures and 30 bimanual gestures, totaling more than 10 hours of recording. We also introduce a benchmark with three tasks -- EMG-to-pose, vision-to-pose, and EMG+vision fusion -- under a shared joint-angle prediction target and common generalization split axes (cross-gesture, cross-user, and combined). As baselines, we evaluate EMGFormer for EMG-to-pose and generic ResNet/ViT backbones for vision-to-pose. We further study a residual fusion architecture that improves over matched lightweight vision-only baselines. Together, EgoEMG and its benchmark establish a foundation for future research on multimodal hand pose estimation with EMG and vision.

  • 6 authors
·
May 6

MyoMechanix: Biomechanically-Grounded Compositional Skilled Activity Understanding and Coaching

Existing action quality assessment (AQA) datasets and methods rely primarily on visual inputs such as RGB and pose, overlooking physiological dynamics such as muscle mechanics and often modeling actions as monolithic patterns. These limitations hinder fine-grained, biomechanically grounded feedback. We introduce MyoMechanix, a multimodal ecosystem for weight-loaded actions that aligns motion with muscle activity. Expert-annotated, it contains 7,500+ samples of 20 actions from 38 subjects, with synchronized multiview RGB video, 3D pose, sEMG, and additional physiological signals, forming the largest multimodal AQA benchmark to date. We further construct the Fitness Knowledge Graph (FKG), which organizes expert annotations into structured relationships among actions, phases, key steps, errors, and corrective feedback, enabling compositional scoring and interpretable assessment. Building on these representations, we develop CUBIST (Compositional Ontological Reasoning Engine), which performs decomposition-analysis-recomposition for fine-grained error attribution and feedback generation. We also establish MyoMechanix-AQA, MyoMechanix-VideoQA, and a novel MyoMechanix-Video2EMG task. Experiments show that multimodal sensing and structured representations improve performance, interpretability, and error attribution, with CUBIST achieving state-of-the-art results; VideoQA enhances language-grounded action understanding; and Video2EMG suggests video-based alternatives to costly EMG sensing. MyoMechanix advances skilled activity understanding toward biomechanically grounded, multimodal, and compositional reasoning for Physical AI applications in fitness, rehabilitation, healthcare, and machine learning. Project page: https://haoyin116.github.io/MyoMechanix/

  • 9 authors
·
Aug 25

TinyMyo: a Tiny Foundation Model for Flexible EMG Signal Processing at the Edge

Surface electromyography (EMG) is a non-invasive sensing modality used in several domains, including biomechanics, rehabilitation, prosthetic control, and emerging human-machine interaction paradigms. Despite decades of use, significant challenges remain in achieving robust generalization across subjects, recording systems, and acquisition protocols. To tackle these challenges, foundation models (FMs) are gaining traction when targeting end-to-end applications based on EMG signals. Yet, existing EMG FMs remain limited to single downstream tasks and lack deployability on embedded platforms. In this work, we present TinyMyo, a lightweight FM based on a Transformer encoder architecture. The model is pre-trained in a self-supervised manner on publicly available datasets and achieves high reconstruction fidelity with only 3.6M parameters. With minimal task-specific head adaptations, the same backbone is used to tackle multiple downstream tasks, leveraging datasets acquired from diverse sensing locations and hardware platforms. We demonstrate generalization across hand gesture classification, hand kinematic regression, speech production and recognition, with performance comparable to or surpassing the state of the art (SoA), and model size below 5M parameters. We achieve SoA results compared to previous FM-based works on the NinaPro DB5 (89.4pm0.16%), UCI-EMG (97.56pm0.32%), and EPN-612 (96.74pm0.09%) datasets. We report, to the best of our knowledge, the first deployment of an EMG FM on an ultra-low-power microcontroller (GAP9), achieving an average power envelope of 36.45mW. By open-sourcing the pre-trained and the downstream task architectures (https://github.com/pulp-bio/BioFoundation), we aim to provide a flexible resource that can accelerate future research and serve as a common foundation for the EMG community.

PulpBio Pulp Platform Bio
·
Dec 5, 2025

Upper Limb Movement Recognition utilising EEG and EMG Signals for Rehabilitative Robotics

Upper limb movement classification, which maps input signals to the target activities, is a key building block in the control of rehabilitative robotics. Classifiers are trained for the rehabilitative system to comprehend the desires of the patient whose upper limbs do not function properly. Electromyography (EMG) signals and Electroencephalography (EEG) signals are used widely for upper limb movement classification. By analysing the classification results of the real-time EEG and EMG signals, the system can understand the intention of the user and predict the events that one would like to carry out. Accordingly, it will provide external help to the user. However, the noise in the real-time EEG and EMG data collection process contaminates the effectiveness of the data, which undermines classification performance. Moreover, not all patients process strong EMG signals due to muscle damage and neuromuscular disorder. To address these issues, this paper explores different feature extraction techniques and machine learning and deep learning models for EEG and EMG signals classification and proposes a novel decision-level multisensor fusion technique to integrate EEG signals with EMG signals. This system retrieves effective information from both sources to understand and predict the desire of the user, and thus aid. By testing out the proposed technique on a publicly available WAY-EEG-GAL dataset, which contains EEG and EMG signals that were recorded simultaneously, we manage to conclude the feasibility and effectiveness of the novel system.

  • 2 authors
·
Jul 18, 2022

Tiny-BioMoE: a Lightweight Embedding Model for Biosignal Analysis

Pain is a complex and pervasive condition that affects a significant portion of the population. Accurate and consistent assessment is essential for individuals suffering from pain, as well as for developing effective management strategies in a healthcare system. Automatic pain assessment systems enable continuous monitoring, support clinical decision-making, and help minimize patient distress while mitigating the risk of functional deterioration. Leveraging physiological signals offers objective and precise insights into a person's state, and their integration in a multimodal framework can further enhance system performance. This study has been submitted to the Second Multimodal Sensing Grand Challenge for Next-Gen Pain Assessment (AI4PAIN). The proposed approach introduces Tiny-BioMoE, a lightweight pretrained embedding model for biosignal analysis. Trained on 4.4 million biosignal image representations and consisting of only 7.3 million parameters, it serves as an effective tool for extracting high-quality embeddings for downstream tasks. Extensive experiments involving electrodermal activity, blood volume pulse, respiratory signals, peripheral oxygen saturation, and their combinations highlight the model's effectiveness across diverse modalities in automatic pain recognition tasks. The model's architecture (code) and weights are available at https://github.com/GkikasStefanos/Tiny-BioMoE.

  • 3 authors
·
Jul 29, 2025

Synchronized AMG and EMG Dataset of Lower-limb Muscle Activities in Everyday Training

Understanding how lower-limb muscle groups coordinate is important for studying movement impairment, rehabilitation, and physical performance. Reproducible analysis of this coordination requires multimodal recordings that relate local muscle-related signals with body-level kinematics. Complementing neural-level electrical activation captured by EMG, AMG provides a valuable mechanical approach to monitoring muscle activity. Here, we introduce a synchronized, multimodal dataset for healthy-adult lower-limb activities. For data collection on the left leg, 16 triaxial accelerometers were evenly divided into four muscle-site clusters for AMG recording, complemented by four surface EMG channels. A 15-marker optical motion-capture (MoCap) system captured lower-body kinematics, with the resulting marker trajectories used to compute bilateral knee and ankle joint angles. Our dataset contains 1,918 trials from 30 subjects across 16 task conditions. We benchmark the dataset by estimating four joint angles from 300 ms windows of the 5-100 Hz band-pass-filtered AMG data and assess matched EMG features in a separate modality ablation. In the primary cross subject benchmark, the four reference models achieved mean absolute errors of 8.840^circ-9.591^circ. The benchmark and ablation results characterize performance across subjects, tasks, and joint angles and examine the effects of sensor configuration, modality, the number of training subjects, and frequency representation. The release includes documented timing definitions, processed data, and reproducible benchmark resources. https://dongxutang918-afk.github.io/SAME-Limb/

  • 5 authors
·
Aug 11

Electroencephalography and Electromyography as a Non-Invasive Biomarker of Neural Regeneration: A Review of Central and Peripheral Nervous System Injury and Regeneration

Regeneration of the nervous system after injury remains an important therapeutic objective, especially in the central nervous system (CNS), in which regeneration is restricted by both neuronal limitations as well as adverse extracellular environments. Conversely, the peripheral nervous system (PNS) displays enhanced regenerative capability in the presence of supportive Schwann cells (SC) and pro-growth stimuli. While the structure and molecular mechanisms are thoroughly understood, functional biomarkers that can non-invasively monitor regeneration in real time are limited. In this review, we discuss the promise of electroencephalography (EEG) as well as electromyography (EMG) as real-time, non-invasive biomarkers to monitor damage to nerves and regeneration in both CNS and PNS contexts. First, we contrast biological and electrophysiological indicators of CNS/PNS injury, showing how EEG signs, including oscillatory power, connectivity, and evoked potential changes, reflect dysfunction due to injury as well as neuroplastic reorganization. Also, EMG provides direct insight into muscle activation and peripheral output, providing useful EEG complementation in neuromuscular pathway integrity and reactivation. In CNS injuries (e.g., stroke, spinal cord injury (SCI)), EEG typically shows global slowing, disrupted interhemispheric coherence, and partial recovery of higher frequencies. For PNS injuries, EEG can capture cortical remapping and return of somatosensory evoked responses with re-establishment of the peripheries' connectivity. EMG, in turn, enables monitoring of reinnervation and restoration of functional motor output. This review presents a dual-system perspective, positioning EEG and EMG not only as diagnostic tools but also as functional biomarkers of neural regeneration, thereby bridging electrophysiology, plasticity, and clinical recovery.

  • 4 authors
·
May 2

Neural Codecs as Biosignal Tokenizers

Neurophysiological recordings such as electroencephalography (EEG) offer accessible and minimally invasive means of estimating physiological activity for applications in healthcare, diagnostic screening, and even immersive entertainment. However, these recordings yield high-dimensional, noisy time-series data that typically require extensive pre-processing and handcrafted feature extraction to reveal meaningful information. Recently, there has been a surge of interest in applying representation learning techniques from large pre-trained (foundation) models to effectively decode and interpret biosignals. We discuss the challenges posed for incorporating such methods and introduce BioCodec, an alternative representation learning framework inspired by neural codecs to capture low-level signal characteristics in the form of discrete tokens. Pre-trained on thousands of EEG hours, BioCodec shows efficacy across multiple downstream tasks, ranging from clinical diagnostic tasks and sleep physiology to decoding speech and motor imagery, particularly in low-resource settings. Additionally, we provide a qualitative analysis of codebook usage and estimate the spatial coherence of codebook embeddings from EEG connectivity. Notably, we also document the suitability of our method to other biosignal data, i.e., electromyographic (EMG) signals. Overall, the proposed approach provides a versatile solution for biosignal tokenization that performs competitively with state-of-the-art models. The source code and model checkpoints are shared.

  • 7 authors
·
Oct 10, 2025

High-density Electromyography for Effective Gesture-based Control of Physically Assistive Mobile Manipulators

Injury to the cervical spinal cord can cause quadriplegia, impairing muscle function in all four limbs. People with impaired hand function and mobility encounter significant difficulties in carrying out essential self-care and household tasks. Despite the impairment of their neural drive, their volitional myoelectric activity is often partially preserved. High-density electromyography (HDEMG) can detect this myoelectric activity, which can serve as control inputs to assistive devices. Previous HDEMG-controlled robotic interfaces have primarily been limited to controlling table-mounted robot arms. These have constrained reach capabilities. Instead, the ability to control mobile manipulators, which have no such workspace constraints, could allow individuals with quadriplegia to perform a greater variety of assistive tasks, thus restoring independence and reducing caregiver workload. In this study, we introduce a non-invasive wearable HDEMG interface with real-time myoelectric hand gesture recognition, enabling both coarse and fine control over the intricate mobility and manipulation functionalities of an 8 degree-of-freedom mobile manipulator. Our evaluation, involving 13 participants engaging in challenging self-care and household activities, demonstrates the potential of our wearable HDEMG system to profoundly enhance user independence by enabling non-invasive control of a mobile manipulator.

  • 4 authors
·
Dec 12, 2023

Pain level and pain-related behaviour classification using GRU-based sparsely-connected RNNs

There is a growing body of studies on applying deep learning to biometrics analysis. Certain circumstances, however, could impair the objective measures and accuracy of the proposed biometric data analysis methods. For instance, people with chronic pain (CP) unconsciously adapt specific body movements to protect themselves from injury or additional pain. Because there is no dedicated benchmark database to analyse this correlation, we considered one of the specific circumstances that potentially influence a person's biometrics during daily activities in this study and classified pain level and pain-related behaviour in the EmoPain database. To achieve this, we proposed a sparsely-connected recurrent neural networks (s-RNNs) ensemble with the gated recurrent unit (GRU) that incorporates multiple autoencoders using a shared training framework. This architecture is fed by multidimensional data collected from inertial measurement unit (IMU) and surface electromyography (sEMG) sensors. Furthermore, to compensate for variations in the temporal dimension that may not be perfectly represented in the latent space of s-RNNs, we fused hand-crafted features derived from information-theoretic approaches with represented features in the shared hidden state. We conducted several experiments which indicate that the proposed method outperforms the state-of-the-art approaches in classifying both pain level and pain-related behaviour.

  • 5 authors
·
Dec 20, 2022

Removing Neural Signal Artifacts with Autoencoder-Targeted Adversarial Transformers (AT-AT)

Electromyogenic (EMG) noise is a major contamination source in EEG data that can impede accurate analysis of brain-specific neural activity. Recent literature on EMG artifact removal has moved beyond traditional linear algorithms in favor of machine learning-based systems. However, existing deep learning-based filtration methods often have large compute footprints and prohibitively long training times. In this study, we present a new machine learning-based system for filtering EMG interference from EEG data using an autoencoder-targeted adversarial transformer (AT-AT). By leveraging the lightweight expressivity of an autoencoder to determine optimal time-series transformer application sites, our AT-AT architecture achieves a >90% model size reduction compared to published artifact removal models. The addition of adversarial training ensures that filtered signals adhere to the fundamental characteristics of EEG data. We trained AT-AT using published neural data from 67 subjects and found that the system was able to achieve comparable test performance to larger models; AT-AT posted a mean reconstructive correlation coefficient above 0.95 at an initial signal-to-noise ratio (SNR) of 2 dB and 0.70 at -7 dB SNR. Further research generalizing these results to broader sample sizes beyond these isolated test cases will be crucial; while outside the scope of this study, we also include results from a real-world deployment of AT-AT in the Appendix.

  • 1 authors
·
Feb 7, 2025

MedTsLLM: Leveraging LLMs for Multimodal Medical Time Series Analysis

The complexity and heterogeneity of data in many real-world applications pose significant challenges for traditional machine learning and signal processing techniques. For instance, in medicine, effective analysis of diverse physiological signals is crucial for patient monitoring and clinical decision-making and yet highly challenging. We introduce MedTsLLM, a general multimodal large language model (LLM) framework that effectively integrates time series data and rich contextual information in the form of text to analyze physiological signals, performing three tasks with clinical relevance: semantic segmentation, boundary detection, and anomaly detection in time series. These critical tasks enable deeper analysis of physiological signals and can provide actionable insights for clinicians. We utilize a reprogramming layer to align embeddings of time series patches with a pretrained LLM's embedding space and make effective use of raw time series, in conjunction with textual context. Given the multivariate nature of medical datasets, we develop methods to handle multiple covariates. We additionally tailor the text prompt to include patient-specific information. Our model outperforms state-of-the-art baselines, including deep learning models, other LLMs, and clinical methods across multiple medical domains, specifically electrocardiograms and respiratory waveforms. MedTsLLM presents a promising step towards harnessing the power of LLMs for medical time series analysis that can elevate data-driven tools for clinicians and improve patient outcomes.

  • 7 authors
·
Aug 13, 2024

A Simple Review of EEG Foundation Models: Datasets, Advancements and Future Perspectives

Electroencephalogram (EEG) signals play a crucial role in understanding brain activity and diagnosing neurological diseases. Because supervised EEG encoders are unable to learn robust EEG patterns and rely too heavily on expensive signal annotation, research has turned to general-purpose self-supervised EEG encoders, known as EEG-based models (EEG-FMs), to achieve robust and scalable EEG feature extraction. However, the readiness of early EEG-FMs for practical applications and the standards for long-term research progress remain unclear. Therefore, a systematic and comprehensive review of first-generation EEG-FMs is necessary to understand their current state-of-the-art and identify key directions for future EEG-FMs. To this end, this study reviews 14 early EEG-FMs and provides a critical comprehensive analysis of their methodologies, empirical findings, and unaddressed research gaps. This review focuses on the latest developments in EEG-based models (EEG-FMs), which have shown great potential for processing and analyzing EEG data. We discuss various EEG-FMs, including their architectures, pretraining strategies, pretraining and downstream datasets, and other details. This review also highlights challenges and future directions in the field, aiming to provide a comprehensive overview for researchers and practitioners interested in EEG analysis and related EEG-FM.

  • 4 authors
·
Apr 24, 2025

RISE Controller Tuning and System Identification Through Machine Learning for Human Lower Limb Rehabilitation via Neuromuscular Electrical Stimulation

Neuromuscular electrical stimulation (NMES) has been effectively applied in many rehabilitation treatments of individuals with spinal cord injury (SCI). In this context, we introduce a novel, robust, and intelligent control-based methodology to closed-loop NMES systems. Our approach utilizes a robust control law to guarantee system stability and machine learning tools to optimize both the controller parameters and system identification. Regarding the latter, we introduce the use of past rehabilitation data to build more realistic data-driven identified models. Furthermore, we apply the proposed methodology for the rehabilitation of lower limbs using a control technique named the robust integral of the sign of the error (RISE), an offline improved genetic algorithm optimizer, and neural network models. Although in the literature, the RISE controller presented good results on healthy subjects, without any fine-tuning method, a trial and error approach would quickly lead to muscle fatigue for individuals with SCI. In this paper, for the first time, the RISE controller is evaluated with two paraplegic subjects in one stimulation session and with seven healthy individuals in at least two and at most five sessions. The results showed that the proposed approach provided a better control performance than empirical tuning, which can avoid premature fatigue on NMES-based clinical procedures.

  • 7 authors
·
Jun 28, 2020

Multimodal Sleep Stage and Sleep Apnea Classification Using Vision Transformer: A Multitask Explainable Learning Approach

Sleep is an essential component of human physiology, contributing significantly to overall health and quality of life. Accurate sleep staging and disorder detection are crucial for assessing sleep quality. Studies in the literature have proposed PSG-based approaches and machine-learning methods utilizing single-modality signals. However, existing methods often lack multimodal, multilabel frameworks and address sleep stages and disorders classification separately. In this paper, we propose a 1D-Vision Transformer for simultaneous classification of sleep stages and sleep disorders. Our method exploits the sleep disorders' correlation with specific sleep stage patterns and performs a simultaneous identification of a sleep stage and sleep disorder. The model is trained and tested using multimodal-multilabel sensory data (including photoplethysmogram, respiratory flow, and respiratory effort signals). The proposed method shows an overall accuracy (cohen's Kappa) of 78% (0.66) for five-stage sleep classification and 74% (0.58) for sleep apnea classification. Moreover, we analyzed the encoder attention weights to clarify our models' predictions and investigate the influence different features have on the models' outputs. The result shows that identified patterns, such as respiratory troughs and peaks, make a higher contribution to the final classification process.

  • 6 authors
·
Feb 18, 2025

Real-time accident detection and physiological signal monitoring to enhance motorbike safety and emergency response

Rapid urbanization and improved living standards have led to a substantial increase in the number of vehicles on the road, consequently resulting in a rise in the frequency of accidents. Among these accidents, motorbike accidents pose a particularly high risk, often resulting in serious injuries or deaths. A significant number of these fatalities occur due to delayed or inadequate medical attention. To this end, we propose a novel automatic detection and notification system specifically designed for motorbike accidents. The proposed system comprises two key components: a detection system and a physiological signal monitoring system. The detection system is integrated into the helmet and consists of a microcontroller, accelerometer, GPS, GSM, and Wi-Fi modules. The physio-monitoring system incorporates a sensor for monitoring pulse rate and SpO_{2} saturation. All collected data are presented on an LCD display and wirelessly transmitted to the detection system through the microcontroller of the physiological signal monitoring system. If the accelerometer readings consistently deviate from the specified threshold decided through extensive experimentation, the system identifies the event as an accident and transmits the victim's information -- including the GPS location, pulse rate, and SpO_{2} saturation rate -- to the designated emergency contacts. Preliminary results demonstrate the efficacy of the proposed system in accurately detecting motorbike accidents and promptly alerting emergency contacts. We firmly believe that the proposed system has the potential to significantly mitigate the risks associated with motorbike accidents and save lives.

  • 7 authors
·
Mar 27, 2024

Physiology-Aware Masked Cross-Modal Reconstruction for Biosignal Representation Learning

Biosignals acquired from different locations on the body often provide temporally ordered views of the same underlying physiological process. However, most existing self supervised learning methods treat these signals as interchangeable views, overlooking the directional temporal dynamics that link them. A canonical example is the relationship between electrocardiography (ECG), which captures the electrical activation initiating each heartbeat, and photoplethysmography (PPG), which records the resulting peripheral pulse delayed by vascular dynamics. To capture this structured relationship, we introduce xMAE, a biosignal pretraining framework that leverages masked cross modal reconstruction across temporally ordered biosignals as a training time constraint to encourage physiologically meaningful timing structure in the learned representations. We show that pretraining with xMAE yields representations that outperform both unimodal and multimodal baselines on 15 of 19 downstream tasks, including cardiovascular outcome prediction, abnormal laboratory test detection, sleep staging, and demographic inference, while generalizing across devices, body locations, and acquisition settings. Further analysis suggests that the ECG PPG timing structure is reflected in the learned PPG representations. More broadly, xMAE demonstrates the effectiveness of incorporating temporal structure into multimodal pretraining when signals observe different stages of a shared underlying process. Code is available at https://github.com/hzhou3/xMAE.

  • 15 authors
·
Apr 30

SCI: A Metacognitive Control for Signal Dynamics

Modern deep learning systems are typically deployed as open-loop function approximators: they map inputs to outputs in a single pass, without regulating how much computation or explanatory effort is spent on a given case. In safety-critical settings, this is brittle: easy and ambiguous inputs receive identical processing, and uncertainty is only read off retrospectively from raw probabilities. We introduce the Surgical Cognitive Interpreter (SCI), a lightweight closed-loop metacognitive control layer that wraps an existing stochastic model and turns prediction into an iterative process. SCI monitors a scalar interpretive state SP(t), here instantiated as a normalized entropy-based confidence signal, and adaptively decides whether to stop, continue sampling, or abstain. The goal is not to improve accuracy per se, but to regulate interpretive error ΔSP and expose a safety signal that tracks when the underlying model is likely to fail. We instantiate SCI around Monte Carlo dropout classifiers in three domains: vision (MNIST digits), medical time series (MIT-BIH arrhythmia), and industrial condition monitoring (rolling-element bearings). In all cases, the controller allocates more inference steps to misclassified inputs than to correct ones (up to about 3-4x on MNIST and bearings, and 1.4x on MIT-BIH). The resulting ΔSP acts as a usable safety signal for detecting misclassifications (AUROC 0.63 on MNIST, 0.70 on MIT-BIH, 0.86 on bearings). Code and reproducibility: https://github.com/vishal-1344/sci

  • 1 authors
·
Nov 15, 2025

Cross-Modality Investigation on WESAD Stress Classification

Deep learning's growing prevalence has driven its widespread use in healthcare, where AI and sensor advancements enhance diagnosis, treatment, and monitoring. In mobile health, AI-powered tools enable early diagnosis and continuous monitoring of conditions like stress. Wearable technologies and multimodal physiological data have made stress detection increasingly viable, but model efficacy depends on data quality, quantity, and modality. This study develops transformer models for stress detection using the WESAD dataset, training on electrocardiograms (ECG), electrodermal activity (EDA), electromyography (EMG), respiration rate (RESP), temperature (TEMP), and 3-axis accelerometer (ACC) signals. The results demonstrate the effectiveness of single-modality transformers in analyzing physiological signals, achieving state-of-the-art performance with accuracy, precision and recall values in the range of 99.73% to 99.95% for stress detection. Furthermore, this study explores cross-modal performance and also explains the same using 2D visualization of the learned embedding space and quantitative analysis based on data variance. Despite the large body of work on stress detection and monitoring, the robustness and generalization of these models across different modalities has not been explored. This research represents one of the initial efforts to interpret embedding spaces for stress detection, providing valuable information on cross-modal performance.

  • 2 authors
·
Feb 25, 2025

EEGNet: A Compact Convolutional Network for EEG-based Brain-Computer Interfaces

Brain computer interfaces (BCI) enable direct communication with a computer, using neural activity as the control signal. This neural signal is generally chosen from a variety of well-studied electroencephalogram (EEG) signals. For a given BCI paradigm, feature extractors and classifiers are tailored to the distinct characteristics of its expected EEG control signal, limiting its application to that specific signal. Convolutional Neural Networks (CNNs), which have been used in computer vision and speech recognition, have successfully been applied to EEG-based BCIs; however, they have mainly been applied to single BCI paradigms and thus it remains unclear how these architectures generalize to other paradigms. Here, we ask if we can design a single CNN architecture to accurately classify EEG signals from different BCI paradigms, while simultaneously being as compact as possible. In this work we introduce EEGNet, a compact convolutional network for EEG-based BCIs. We introduce the use of depthwise and separable convolutions to construct an EEG-specific model which encapsulates well-known EEG feature extraction concepts for BCI. We compare EEGNet to current state-of-the-art approaches across four BCI paradigms: P300 visual-evoked potentials, error-related negativity responses (ERN), movement-related cortical potentials (MRCP), and sensory motor rhythms (SMR). We show that EEGNet generalizes across paradigms better than the reference algorithms when only limited training data is available. We demonstrate three different approaches to visualize the contents of a trained EEGNet model to enable interpretation of the learned features. Our results suggest that EEGNet is robust enough to learn a wide variety of interpretable features over a range of BCI tasks, suggesting that the observed performances were not due to artifact or noise sources in the data.

  • 6 authors
·
May 15, 2018

SigmaMedStat: Temporal Signal Modeling for ICU False Alarm Reduction

Alarm fatigue in intensive care units (ICUs) is a well documented patient safety crisis. Clinical monitors generate 350 or more alarms per patient per day, out of which 72-99% are clinically irrelevant. Staff desensitization to non-actionable alarms increases the risk of missed true emergencies. This paper presents SigmaMedStat, a machine learning system that evaluates the trustworthiness of physiological alarm signals before clinical action is taken. Four approaches were evaluated on the PhysioNet/Computing in Cardiology Challenge 2015 dataset of 498 four-channel ICU alarm recordings. Primary contribution is a temporal modeling framework that splits each 60 second recording into six consecutive 10-second chunks, and this in turn generates Continuous Wavelet Transform (CWT) scalograms per chunk, encodes each chunk with a shared EfficientNet-B0 encoder, and passes the resulting feature sequence to a two-layer Long Short-Term Memory (LSTM) network. Five-fold stratified cross-validation yields a mean AUC of 0.822 +/- 0.016 (95% CI: [0.790,0.853]), compared to 0.641 for a static EfficientNet baseline trained on the full 60-second window. Ablation studies confirm that temporal chunking and multi-channel signal fusion both contribute independently to classification performance. Per-alarm type analysis reveals that Ventricular Flutter is the most accurately classified alarm type (AUC 0.820) while Asystole remains the hardest (AUC 0.722). Error analysis identifies 65 false negatives and 85 high-confidence misclassifications as the primary failure modes. All code and results are publicly available at https://github.com/Arun-K-Ram/sigmamedstat.

  • 1 authors
·
May 27

SilentWear: an Ultra-Low Power Wearable System for EMG-based Silent Speech Recognition

Detecting speech from biosignals is gaining increasing attention due to the potential to develop human-computer interfaces that are noise-robust, privacy-preserving, and scalable for both clinical applications and daily use. However, most existing approaches remain limited by insufficient wearability and the lack of edge-processing capabilities, which are essential for minimally obtrusive, responsive, and private assistive technologies. In this work, we present SilentWear, a fully wearable, textile-based neck interface for EMG signal acquisition and processing. Powered by BioGAP-Ultra, the system enables end-to-end data acquisition from 14 differential channels and on-device speech recognition. SilentWear is coupled with SpeechNet, a lightweight 15k-parameter CNN architecture specifically tailored for EMG-based speech decoding, achieving an average cross-validated accuracy of 84.8pm4.6% and 77.5pm6.6% for vocalized and silent speech, respectively, over eight representative human-machine interaction commands collected over multiple days. We evaluate robustness to repositioning induced by multi-day use. In an inter-session setting, the system achieves average accuracies of 71.1pm8.3% and 59.3\pm2.2% for vocalized and silent speech, respectively. To mitigate performance degradation due to repositioning, we propose an incremental fine-tuning strategy, demonstrating more than 10% accuracy recovery with less than 10 minutes of additional user data. Finally, we demonstrate end-to-end real-time on-device speech recognition on a commercial multi-core microcontroller unit (MCU), achieving an energy consumption of 63.9μJ per inference with a latency of 2.47 ms. With a total power consumption of 20.5mW for acquisition, inference, and wireless transmission of results, SilentWear enables continuous operation for more than 27 hours.

  • 8 authors
·
Mar 3

CoRe-ECG: Advancing Self-Supervised Representation Learning for 12-Lead ECG via Contrastive and Reconstructive Synergy

Accurate interpretation of electrocardiogram (ECG) remains challenging due to the scarcity of labeled data and the high cost of expert annotation. Self-supervised learning (SSL) offers a promising solution by enabling models to learn expressive representations from unlabeled signals. Existing ECG SSL methods typically rely on either contrastive learning or reconstructive learning. However, each approach in isolation provides limited supervisory signals and suffers from additional limitations, including non-physiological distortions introduced by naive augmentations and trivial correlations across multiple leads that models may exploit as shortcuts. In this work, we propose CoRe-ECG, a unified contrastive and reconstructive pretraining paradigm that establishes a synergistic interaction between global semantic modeling and local structural learning. CoRe-ECG aligns global representations during reconstruction, enabling instance-level discriminative signals to guide local waveform recovery. To further enhance pretraining, we introduce Frequency Dynamic Augmentation (FDA) to adaptively perturb ECG signals based on their frequency-domain importance, and Spatio-Temporal Dual Masking (STDM) to break linear dependencies across leads, increasing the difficulty of reconstructive tasks. Our method achieves state-of-the-art performance across multiple downstream ECG datasets. Ablation studies further demonstrate the necessity and complementarity of each component. This approach provides a robust and physiologically meaningful representation learning framework for ECG analysis.

  • 9 authors
·
Apr 12

Learning Human Health and Diseases from 24-hour Wrist Movement

Much of human health and function unfolds beyond the clinic, through the movements of everyday life. Wrist-worn accelerometers capture these movements continuously, yet their rich signals are often reduced to a small set of predefined behavioural summary measures. Here, we present Sensori, a self-supervised foundation model that learns general-purpose health representations directly from 24 hours of raw tri-axial wrist movement. We developed and evaluated the model across four population-based cohorts from the United Kingdom, China and the United States, comprising 122,640 participants contributing 683,617 person-days of free-living recordings. Sensori condensed each day of movement into a representation that captured diverse movement behaviours, demographic characteristics, health axes and physical function. Evaluation in independent cohorts showed that these representations generalised across populations and measurement settings without retraining. When added to common clinical covariates, Sensori significantly improved prevalent disease classification for 52 of 102 eligible conditions (median delta AUROC, 0.060; range, 0.012-0.242) and incident disease risk prediction for 26 of 87 eligible conditions (median delta Uno's C-index, 0.064; range, 0.025-0.172), with the largest gains for neurological and psychiatric disorders. These findings establish 24-hour wrist movement as a rich and scalable source of health information, with the potential to support passive health monitoring and disease prediction at population scale.

  • 24 authors
·
Aug 29

Next-Token Prediction Learns Generalisable Representations of Sleep Physiology

Foundation models offer a promising route to compress multi-modal physiological signals into compact representations of human health, with broad applications across sleep medicine, cardiology, neurology and other healthcare domains. Existing models have typically been trained with masked-reconstruction or contrastive objectives. However, masked reconstruction may be poorly suited to the stochastic nature of these signals, while contrastive approaches rely on positive-pair definitions despite the semantic invariances of physiological signals being poorly understood. In this work, we show that next-token prediction is a simple and scalable alternative. We develop Hypnos, a multi-modal sleep foundation model trained using eight different sensing modalities (e.g. EEG, ECG, respiratory signals) drawn from over 20,000 overnight polysomnography recordings. We tokenize each modality into streams of discrete tokens using residual vector quantization, then train a large auto-regressive RQ-Transformer to jointly predict the next token across all modalities in parallel. After training, Hypnos can be applied to continuous streams of sensor data from any subset of supported modalities, generating embeddings for downstream tasks. Across a range of benchmarks, Hypnos significantly outperforms existing foundation models. In sleep stage classification, we match the performance of strong supervised baselines on held-out test sets whilst using \(100\times\) less labelled data. Hypnos even generalises to daytime physiology, surpassing a dedicated ECG foundation model at detecting atrial fibrillation. Our results demonstrate that next-token prediction is a strong self-supervised objective for representation learning from multi-modal physiological signals.

  • 2 authors
·
Jun 7

Adversarial Approximate Inference for Speech to Electroglottograph Conversion

Speech produced by human vocal apparatus conveys substantial non-semantic information including the gender of the speaker, voice quality, affective state, abnormalities in the vocal apparatus etc. Such information is attributed to the properties of the voice source signal, which is usually estimated from the speech signal. However, most of the source estimation techniques depend heavily on the goodness of the model assumptions and are prone to noise. A popular alternative is to indirectly obtain the source information through the Electroglottographic (EGG) signal that measures the electrical admittance around the vocal folds using dedicated hardware. In this paper, we address the problem of estimating the EGG signal directly from the speech signal, devoid of any hardware. Sampling from the intractable conditional distribution of the EGG signal given the speech signal is accomplished through optimization of an evidence lower bound. This is constructed via minimization of the KL-divergence between the true and the approximated posteriors of a latent variable learned using a deep neural auto-encoder that serves an informative prior. We demonstrate the efficacy of the method at generating the EGG signal by conducting several experiments on datasets comprising multiple speakers, voice qualities, noise settings and speech pathologies. The proposed method is evaluated on many benchmark metrics and is found to agree with the gold standard while proving better than the state-of-the-art algorithms on a few tasks such as epoch extraction.

  • 3 authors
·
Mar 28, 2019 2

A portable solution for simultaneous human movement and mobile EEG acquisition: readiness potential for basketball free-throw shooting

Advances in wireless electroencephalography (EEG) technology promise to record brain-electrical activity in everyday situations. To better understand the relationship between brain activity and natural behavior, it is necessary to monitor human movement patterns. Here, we present a pocketable setup consisting of two smartphones to simultaneously capture human posture and EEG signals. We asked 26 basketball players to shoot 120 free throws each. First, we investigated whether our setup allows us to capture the readiness potential (RP) that precedes voluntary actions. Second, we investigated whether the RP differs between successful and unsuccessful free-throw attempts. The results confirmed the presence of the RP over fronto-central channels, with significant negative deflection at channel Cz, from -400 to 0 ms before movement onset (M pm SE: -6.54 pm 2.26 to -13.52 pm 2.42 μV; z = -2.53 to -3.92; FDR-corrected p = 0.049 to 0.003; r = 0.50 to 0.77). However, the amplitude of the RP was not related to shooting success (all FDR-corrected p > 0.05; maximum mean R^2 = 0.047, i.e., 4.7% explained variance). Preliminary exploratory pose analysis conducted offline indicated the presence of participant-specific variations in posture between successful and unsuccessful shots in 38.5% of participants (10/26), with 4.5% explained variance (maximum mean landmark R^2 = 0.045). We conclude that a highly portable, low-cost and lightweight acquisition setup, consisting of two smartphones and a head-mounted wireless EEG amplifier, is sufficient to monitor complex human movement patterns and associated brain dynamics outside the laboratory.

  • 6 authors
·
Jul 19 1

Reliable Physiological Monitoring on the Wrist Using Generative Deep Learning to Address Poor Skin-Sensor Contact

Photoplethysmography (PPG) is a widely adopted, non-invasive technique for monitoring cardiovascular health and physiological parameters in both consumer and clinical settings. While motion artifacts in dynamic environments have been extensively studied, suboptimal skin-sensor contact in sedentary conditions - a critical yet underexplored issue - can distort PPG waveform morphology, leading to the loss or misalignment of key features and compromising sensing accuracy. In this work, we propose CP-PPG, a novel framework that transforms Contact Pressure-distorted PPG signals into high-fidelity waveforms with ideal morphology. CP-PPG integrates a custom data collection protocol, a carefully designed signal processing pipeline, and a novel deep adversarial model trained with a custom PPG-aware loss function. We validated CP-PPG through comprehensive evaluations, including 1) morphology transformation performance on our self-collected dataset, 2) downstream physiological monitoring performance on public datasets, and 3) in-the-wild study. Extensive experiments demonstrate substantial and consistent improvements in signal fidelity (Mean Absolute Error: 0.09, 40% improvement over the original signal) as well as downstream performance across all evaluations in Heart Rate (HR), Heart Rate Variability (HRV), Respiration Rate (RR), and Blood Pressure (BP) estimation (on average, 21% improvement in HR; 41-46% in HRV; 6% in RR; and 4-5% in BP). These findings highlight the critical importance of addressing skin-sensor contact issues to enhance the reliability and effectiveness of PPG-based physiological monitoring. CP-PPG thus holds significant potential to improve the accuracy of wearable health technologies in clinical and consumer applications.

  • 6 authors
·
Apr 15, 2025

Large Language Models for Cuffless Blood Pressure Measurement From Wearable Biosignals

Large language models (LLMs) have captured significant interest from both academia and industry due to their impressive performance across various textual tasks. However, the potential of LLMs to analyze physiological time-series data remains an emerging research field. Particularly, there is a notable gap in the utilization of LLMs for analyzing wearable biosignals to achieve cuffless blood pressure (BP) measurement, which is critical for the management of cardiovascular diseases. This paper presents the first work to explore the capacity of LLMs to perform cuffless BP estimation based on wearable biosignals. We extracted physiological features from electrocardiogram (ECG) and photoplethysmogram (PPG) signals and designed context-enhanced prompts by combining these features with BP domain knowledge and user information. Subsequently, we adapted LLMs to BP estimation tasks through fine-tuning. To evaluate the proposed approach, we conducted assessments of ten advanced LLMs using a comprehensive public dataset of wearable biosignals from 1,272 participants. The experimental results demonstrate that the optimally fine-tuned LLM significantly surpasses conventional task-specific baselines, achieving an estimation error of 0.00 pm 9.25 mmHg for systolic BP and 1.29 pm 6.37 mmHg for diastolic BP. Notably, the ablation studies highlight the benefits of our context enhancement strategy, leading to an 8.9% reduction in mean absolute error for systolic BP estimation. This paper pioneers the exploration of LLMs for cuffless BP measurement, providing a potential solution to enhance the accuracy of cuffless BP measurement.

  • 8 authors
·
Jun 26, 2024

Tokenizing Single-Channel EEG with Time-Frequency Motif Learning

Foundation models are reshaping EEG analysis, yet an important problem of EEG tokenization remains a challenge. This paper presents TFM-Tokenizer, a novel tokenization framework that learns a vocabulary of time-frequency motifs from single-channel EEG signals and encodes them into discrete tokens. We propose a dual-path architecture with time-frequency masking to capture robust motif representations, and it is model-agnostic, supporting both lightweight transformers and existing foundation models for downstream tasks. Our study demonstrates three key benefits: Accuracy: Experiments on four diverse EEG benchmarks demonstrate consistent performance gains across both single- and multi-dataset pretraining settings, achieving up to 17% improvement in Cohen's Kappa over strong baselines. Generalization: Moreover, as a plug-and-play component, it consistently boosts the performance of diverse foundation models, including BIOT and LaBraM. Scalability: By operating at the single-channel level rather than relying on the strict 10-20 EEG system, our method has the potential to be device-agnostic. Experiments on ear-EEG sleep staging, which differs from the pretraining data in signal format, channel configuration, recording device, and task, show that our tokenizer outperforms baselines by 14%. A comprehensive token analysis reveals strong class-discriminative, frequency-aware, and consistent structure, enabling improved representation quality and interpretability. Code is available at https://github.com/Jathurshan0330/TFM-Tokenizer.

  • 4 authors
·
Feb 21, 2025

Invisible Ears at Your Fingertips: Acoustic Eavesdropping via Mouse Sensors

Modern optical mouse sensors, with their advanced precision and high responsiveness, possess an often overlooked vulnerability: they can be exploited for side-channel attacks. This paper introduces Mic-E-Mouse, the first-ever side-channel attack that targets high-performance optical mouse sensors to covertly eavesdrop on users. We demonstrate that audio signals can induce subtle surface vibrations detectable by a mouse's optical sensor. Remarkably, user-space software on popular operating systems can collect and broadcast this sensitive side channel, granting attackers access to raw mouse data without requiring direct system-level permissions. Initially, the vibration signals extracted from mouse data are of poor quality due to non-uniform sampling, a non-linear frequency response, and significant quantization. To overcome these limitations, Mic-E-Mouse employs a sophisticated end-to-end data filtering pipeline that combines Wiener filtering, resampling corrections, and an innovative encoder-only spectrogram neural filtering technique. We evaluate the attack's efficacy across diverse conditions, including speaking volume, mouse polling rate and DPI, surface materials, speaker languages, and environmental noise. In controlled environments, Mic-E-Mouse improves the signal-to-noise ratio (SNR) by up to +19 dB for speech reconstruction. Furthermore, our results demonstrate a speech recognition accuracy of roughly 42% to 61% on the AudioMNIST and VCTK datasets. All our code and datasets are publicly accessible on https://sites.google.com/view/mic-e-mouse.

  • 5 authors
·
Nov 16, 2025

EEG-based Cross-Subject Driver Drowsiness Recognition with an Interpretable Convolutional Neural Network

In the context of electroencephalogram (EEG)-based driver drowsiness recognition, it is still challenging to design a calibration-free system, since EEG signals vary significantly among different subjects and recording sessions. Many efforts have been made to use deep learning methods for mental state recognition from EEG signals. However, existing work mostly treats deep learning models as black-box classifiers, while what have been learned by the models and to which extent they are affected by the noise in EEG data are still underexplored. In this paper, we develop a novel convolutional neural network combined with an interpretation technique that allows sample-wise analysis of important features for classification. The network has a compact structure and takes advantage of separable convolutions to process the EEG signals in a spatial-temporal sequence. Results show that the model achieves an average accuracy of 78.35% on 11 subjects for leave-one-out cross-subject drowsiness recognition, which is higher than the conventional baseline methods of 53.40%-72.68% and state-of-the-art deep learning methods of 71.75%-75.19%. Interpretation results indicate the model has learned to recognize biologically meaningful features from EEG signals, e.g., Alpha spindles, as strong indicators of drowsiness across different subjects. In addition, we also explore reasons behind some wrongly classified samples with the interpretation technique and discuss potential ways to improve the recognition accuracy. Our work illustrates a promising direction on using interpretable deep learning models to discover meaningful patterns related to different mental states from complex EEG signals.

  • 4 authors
·
May 30, 2021

QualityFM: a Multimodal Physiological Signal Foundation Model with Self-Distillation for Signal Quality Challenges in Critically Ill Patients

Photoplethysmogram (PPG) and electrocardiogram (ECG) are commonly recorded in intesive care unit (ICU) and operating room (OR). However, the high incidence of poor, incomplete, and inconsistent signal quality, can lead to false alarms or diagnostic inaccuracies. The methods explored so far suffer from limited generalizability, reliance on extensive labeled data, and poor cross-task transferability. To overcome these challenges, we introduce QualityFM, a novel multimodal foundation model for these physiological signals, designed to acquire a general-purpose understanding of signal quality. Our model is pre-trained on an large-scale dataset comprising over 21 million 30-second waveforms and 179,757 hours of data. Our approach involves a dual-track architecture that processes paired physiological signals of differing quality, leveraging a self-distillation strategy where an encoder for high-quality signals is used to guide the training of an encoder for low-quality signals. To efficiently handle long sequential signals and capture essential local quasi-periodic patterns, we integrate a windowed sparse attention mechanism within our Transformer-based model. Furthermore, a composite loss function, which combines direct distillation loss on encoder outputs with indirect reconstruction loss based on power and phase spectra, ensures the preservation of frequency-domain characteristics of the signals. We pre-train three models with varying parameter counts (9.6 M to 319 M) and demonstrate their efficacy and practical value through transfer learning on three distinct clinical tasks: false alarm of ventricular tachycardia detection, the identification of atrial fibrillation and the estimation of arterial blood pressure (ABP) from PPG and ECG signals.

  • 3 authors
·
Sep 8, 2025

Mamba-based Deep Learning Approach for Sleep Staging on a Wireless Multimodal Wearable System without Electroencephalography

Study Objectives: We investigate a Mamba-based deep learning approach for sleep staging on signals from ANNE One (Sibel Health, Evanston, IL), a non-intrusive dual-module wireless wearable system measuring chest electrocardiography (ECG), triaxial accelerometry, and chest temperature, and finger photoplethysmography and finger temperature. Methods: We obtained wearable sensor recordings from 357 adults undergoing concurrent polysomnography (PSG) at a tertiary care sleep lab. Each PSG recording was manually scored and these annotations served as ground truth labels for training and evaluation of our models. PSG and wearable sensor data were automatically aligned using their ECG channels with manual confirmation by visual inspection. We trained a Mamba-based recurrent neural network architecture on these recordings. Ensembling of model variants with similar architectures was performed. Results: After ensembling, the model attains a 3-class (wake, non rapid eye movement [NREM] sleep, rapid eye movement [REM] sleep) balanced accuracy of 84.02%, F1 score of 84.23%, Cohen's κ of 72.89%, and a Matthews correlation coefficient (MCC) score of 73.00%; a 4-class (wake, light NREM [N1/N2], deep NREM [N3], REM) balanced accuracy of 75.30%, F1 score of 74.10%, Cohen's κ of 61.51%, and MCC score of 61.95%; a 5-class (wake, N1, N2, N3, REM) balanced accuracy of 65.11%, F1 score of 66.15%, Cohen's κ of 53.23%, MCC score of 54.38%. Conclusions: Our Mamba-based deep learning model can successfully infer major sleep stages from the ANNE One, a wearable system without electroencephalography (EEG), and can be applied to data from adults attending a tertiary care sleep clinic.

  • 12 authors
·
Nov 24, 2025

Representation learning for improved interpretability and classification accuracy of clinical factors from EEG

Despite extensive standardization, diagnostic interviews for mental health disorders encompass substantial subjective judgment. Previous studies have demonstrated that EEG-based neural measures can function as reliable objective correlates of depression, or even predictors of depression and its course. However, their clinical utility has not been fully realized because of 1) the lack of automated ways to deal with the inherent noise associated with EEG data at scale, and 2) the lack of knowledge of which aspects of the EEG signal may be markers of a clinical disorder. Here we adapt an unsupervised pipeline from the recent deep representation learning literature to address these problems by 1) learning a disentangled representation using beta-VAE to denoise the signal, and 2) extracting interpretable features associated with a sparse set of clinical labels using a Symbol-Concept Association Network (SCAN). We demonstrate that our method is able to outperform the canonical hand-engineered baseline classification method on a number of factors, including participant age and depression diagnosis. Furthermore, our method recovers a representation that can be used to automatically extract denoised Event Related Potentials (ERPs) from novel, single EEG trajectories, and supports fast supervised re-mapping to various clinical labels, allowing clinicians to re-use a single EEG representation regardless of updates to the standardized diagnostic system. Finally, single factors of the learned disentangled representations often correspond to meaningful markers of clinical factors, as automatically detected by SCAN, allowing for human interpretability and post-hoc expert analysis of the recommendations made by the model.

  • 9 authors
·
Oct 28, 2020

BioMoDiffuse: Physics-Guided Biomechanical Diffusion for Controllable and Authentic Human Motion Synthesis

Human motion generation holds significant promise in fields such as animation, film production, and robotics. However, existing methods often fail to produce physically plausible movements that adhere to biomechanical principles. While recent autoregressive and diffusion models have improved visual quality, they frequently overlook essential biodynamic features, such as muscle activation patterns and joint coordination, leading to motions that either violate physical laws or lack controllability. This paper introduces BioMoDiffuse, a novel biomechanics-aware diffusion framework that addresses these limitations. It features three key innovations: (1) A lightweight biodynamic network that integrates muscle electromyography (EMG) signals and kinematic features with acceleration constraints, (2) A physics-guided diffusion process that incorporates real-time biomechanical verification via modified Euler-Lagrange equations, and (3) A decoupled control mechanism that allows independent regulation of motion speed and semantic context. We also propose a set of comprehensive evaluation protocols that combines traditional metrics (FID, R-precision, etc.) with new biomechanical criteria (smoothness, foot sliding, floating, etc.). Our approach bridges the gap between data-driven motion synthesis and biomechanical authenticity, establishing new benchmarks for physically accurate motion generation.

  • 3 authors
·
Mar 8, 2025

Large Brain Model for Learning Generic Representations with Tremendous EEG Data in BCI

The current electroencephalogram (EEG) based deep learning models are typically designed for specific datasets and applications in brain-computer interaction (BCI), limiting the scale of the models and thus diminishing their perceptual capabilities and generalizability. Recently, Large Language Models (LLMs) have achieved unprecedented success in text processing, prompting us to explore the capabilities of Large EEG Models (LEMs). We hope that LEMs can break through the limitations of different task types of EEG datasets, and obtain universal perceptual capabilities of EEG signals through unsupervised pre-training. Then the models can be fine-tuned for different downstream tasks. However, compared to text data, the volume of EEG datasets is generally small and the format varies widely. For example, there can be mismatched numbers of electrodes, unequal length data samples, varied task designs, and low signal-to-noise ratio. To overcome these challenges, we propose a unified foundation model for EEG called Large Brain Model (LaBraM). LaBraM enables cross-dataset learning by segmenting the EEG signals into EEG channel patches. Vector-quantized neural spectrum prediction is used to train a semantically rich neural tokenizer that encodes continuous raw EEG channel patches into compact neural codes. We then pre-train neural Transformers by predicting the original neural codes for the masked EEG channel patches. The LaBraMs were pre-trained on about 2,500 hours of various types of EEG signals from around 20 datasets and validated on multiple different types of downstream tasks. Experiments on abnormal detection, event type classification, emotion recognition, and gait prediction show that our LaBraM outperforms all compared SOTA methods in their respective fields. Our code is available at https://github.com/935963004/LaBraM.

  • 3 authors
·
May 28, 2024

Toward World Modeling of Physiological Signals with Chaos-Theoretic Balancing and Latent Dynamics

Physiological time series signals reflect complex, multi-scale dynamical processes of the human body. Existing modeling studies focus on static tasks such as classification, event forecasting, or short-horizon next step prediction, while long-horizon signal-level forecasting and predictive nature of physiological signals remain underexplored. We introduce NormWear-2, a world model that encodes both multivariate physiological signals and clinical intervention variables into a shared latent space and models their joint temporal evolution as a dynamical system. Our approach combines inference from prior pre-trained knowledge (intuition) with instant non-parametric latent state transition adaptation (insight), enabling coherent forecasting across multiple temporal scales, conditioned on heterogeneous clinical interventions. During the pretraining phase, we find that chaos-theoretic balancing of dynamical regime diversity yields more robust representations, with a smaller balanced corpus outperforming one twice its size and capturing bifurcation regimes. We evaluate the world model performance across diverse real-world physiological datasets spanning heterogeneous temporal resolutions and intervention regimes, covering daily life, point-of-care, and clinical settings, including fitness planning, hemodialysis, diabetes management, and surgical monitoring. These evaluation datasets comprise records from 8,026 subjects, spanning study durations from 3.2 hours for high-resolution signal data to 2.3 years for longitudinal clinical biomarker tracking. NormWear-2 achieves the best overall forecasting performance across time, frequency, and latent representation domains, with significant improvements over state-of-the-art time series foundation models, while maintaining competitive downstream representation quality, providing a step toward general-purpose world models for physiological signals.

  • 11 authors
·
May 13

Large-scale Training of Foundation Models for Wearable Biosignals

Tracking biosignals is crucial for monitoring wellness and preempting the development of severe medical conditions. Today, wearable devices can conveniently record various biosignals, creating the opportunity to monitor health status without disruption to one's daily routine. Despite widespread use of wearable devices and existing digital biomarkers, the absence of curated data with annotated medical labels hinders the development of new biomarkers to measure common health conditions. In fact, medical datasets are usually small in comparison to other domains, which is an obstacle for developing neural network models for biosignals. To address this challenge, we have employed self-supervised learning using the unlabeled sensor data collected under informed consent from the large longitudinal Apple Heart and Movement Study (AHMS) to train foundation models for two common biosignals: photoplethysmography (PPG) and electrocardiogram (ECG) recorded on Apple Watch. We curated PPG and ECG datasets from AHMS that include data from ~141K participants spanning ~3 years. Our self-supervised learning framework includes participant level positive pair selection, stochastic augmentation module and a regularized contrastive loss optimized with momentum training, and generalizes well to both PPG and ECG modalities. We show that the pre-trained foundation models readily encode information regarding participants' demographics and health conditions. To the best of our knowledge, this is the first study that builds foundation models using large-scale PPG and ECG data collected via wearable consumer devices x2013 prior works have commonly used smaller-size datasets collected in clinical and experimental settings. We believe PPG and ECG foundation models can enhance future wearable devices by reducing the reliance on labeled data and hold the potential to help the users improve their health.

  • 6 authors
·
Dec 8, 2023